4/2 and 4/3 proportional directional valves, direct operated, without electrical position feedback, without integrated electronics (OBE) 4WRA

min-slider-1

4/2 and 4/3 proportional directional valves, direct operated, without electrical position feedback, without integrated electronics (OBE) 4WRA

  • Size 6, 10
  • Component series 2X
  • Maximum operating pressure 315 bar
  • Maximum flow 75 l/min

Type

4WRA

Size

6 10

Installation position

  any, preferably horizontal

Ambient temperature range

°C

-20 … +70

Storage temperature range

°C

-20 … +80

Weight

kg

2 6.6
 

Size

6 10

Maximum operating pressure

 

bar

315

Maximum operating pressure

Port P

bar

315

Port T

bar

210

Port A

bar

315

Port B

bar

315

Maximum flow

 

l/min

42 75

with double flow

l/min

80 140

Nominal flow

 

l/min

7
15
26
30
60

Hydraulic fluid 1)

    see table

Hydraulic fluid temperature range

 

°C

-20 … +80

preferably

°C

+40 … +50

Viscosity range

 

mm²/s

20 … 380

preferably

mm²/s

30 … 46

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2)

  Class 20/18/15 according to ISO 4406 (c)

Hysteresis

 

%

≤ 5

Range of inversion

 

%

≤ 1

Response sensitivity

 

%

≤ 0.5
 
1) Additional hydraulic fluids upon request
2) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.
 

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils and related hydrocarbons

HL, HLP

NBR / FKM

DIN 51524

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids please contact us.

 

electrical

Size

6 10

Voltage type

  Direct voltage

Maximum solenoid current

 

A

2.5

Maximum current consumption

of the amplifier

A

1.8

of the amplifier (impulse current)

A

3

Solenoid coil resistance

Cold value at 20°C

Ω

2

Maximum hot value

Ω

3

Actuated time

 

%

100

Maximum coil temperature 1)

 

°C

+ 150

Power supply

 

VDC

24

Supply voltage range

 

V

21 … 35
 

 