HESS Hydraulic Equipment Systems and Solutions

Гидравлическое Оборудование Системы и Решения

img
img

Обратная связь

ФИО* e-mail* Телефон* Организация Содержание запроса* Прикрепить файл Выберите файл Введите число с картинки* поменять картинку

Каталог продукции

Бренды

4/2 and 4/3 proportional directional valves, direct operated, without electrical position feedback, with integrated electronics (OBE) 4WRAE

min-slider-1

4/2 and 4/3 proportional directional valves, direct operated, without electrical position feedback, with integrated electronics (OBE) 4WRAE

  • Size 6, 10
  • Component series 2X
  • Maximum operating pressure 315 bar
  • Maximum flow 75 l/min

Type

4WRAE

Size

6 10

Installation position

  any, preferably horizontal

Ambient temperature range

°C

-20 … +50

Storage temperature range

°C

-20 … +80

Weight

kg

2.2 6.8
 

hydraulic

Size

6 10

Maximum operating pressure

 

bar

315

Maximum operating pressure

Port P

bar

315

Port T

bar

210

Port A

bar

315

Port B

bar

315

Maximum flow

 

l/min

42 75

with double flow

l/min

80 140

Nominal flow

 

l/min

7
15
26
30
60

Hydraulic fluid 1)

    Mineral oil (HL, HLP) to DIN 51524

Hydraulic fluid temperature range

 

°C

-20 … +80

preferably

°C

+40 … +50

Viscosity range

 

mm²/s

20 … 380

preferably

mm²/s

30 … 46

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 2)

  Class 20/18/15 according to ISO 4406 (c)

Hysteresis

 

%

≤ 5

Range of inversion

 

%

≤ 1

Response sensitivity

 

%

≤ 0.5
 
1) Additional hydraulic fluids upon request
2) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and simultaneously increases the life cycle of the components. For the selection of the filters, see www.boschrexroth.com/filter.
 

Hydraulic fluid

Classification

Suitable sealing materials

Standards

Mineral oils and related hydrocarbons

HL, HLP

NBR / FKM

DIN 51524

Important information on hydraulic fluids:

For more information and data on the use of other hydraulic fluids please contact us.

 

electrical

Size

6 10

Voltage type

  Direct voltage

Maximum solenoid current

 

A

2.5

Maximum current consumption

of the amplifier

A

1.8

of the amplifier (impulse current)

A

3

Solenoid coil resistance

Cold value at 20°C

Ω

2

Maximum hot value

Ω

3

Actuated time

 

%

100

Maximum coil temperature 1)

 

°C

+ 150

Power supply

 

VDC

24

Supply voltage range

 

V

19 … 35

Command value input

"A1"

V

± 10

Command value input range

"F1"

mA

4 … 20
 

 

Вернуться на уровень выше