Valve amplifiers for proportional pressure valves VT-MSPA1-10-1X

min-slider-1

Valve amplifiers for proportional pressure valves VT-MSPA1-10-1X

  • Component series 1X
  • Analog, Modular design
  • For valves: DBET-6X, DBEM...7x
  • Differential input for voltage
  • Ramp generator with separately adjustable ramp times "up/down"
  • Adjustable zero point and sensitivity
  • Characteristic curve generator
  • Clocked power output stage
  • Dither generator
  • LED displays for various operating states
  • Reverse polarity protection for the operating voltage

Component series

  1X

Type of electronics

  Analog

Design

  Modul
 

 

Analog amplifier for controlling pressure valves without electrical feedback. The modular design allows for simple top hat rail mounting as is usual in control cabinets.

Command value input [4]

The module amplifier is controlled by means of a standard command value signal 0 to +10 V. By means of the zero point potentiometer (Zw) [6], a zero point offset can be corrected.

Ramp generator [5]

In the ramp generator [5], the control output incline is limited. Using the trimmer "t <" [7], the time for the increasing command value signal is set and using trimmer "t >" [8], the time for the decreasing command value voltage is set.

Characteristic curve generator [10]

Using the trimmer "Gw" [9], the rated current of 1.6 A for the solenoid is set. In the characteristic curve generator [10], the command value signal is changed so that a linear command value pressure characteristic curve is created.

Clock generator [12]

In the clock generator [12], a frequency for the output stage

adjusted to the command value is generated.

Power output stage [11]-[14]

Using the control output coming from the characteristic curve generator [10] and the clock frequency, the power output stage generates a PWM signal that is fed into the solenoid. The solenoid current is recorded and, in the current controller [11], compared with the control output and the difference is compensated.

Fault recognition [15]

Monitors the solenoid conductors with reference to cable break and short-circuit as well as over-current of the output stage. If there is an error, the green ready for operation display goes out.