Proportional directional valves, direct operated, with pQ functionality STW 0195, STW 0196

min-slider-1

Proportional directional valves, direct operated, with pQ functionality STW 0195, STW 0196

  • Size 6, 10
  • Component series 2X, 1X
  • 3-way proportional directional valves with integrated digital control electronics IAC-P
  • Completely adjusted unit consisting of position-controlled valve, pressure sensor and field bus connection
  • Operation by means of proportional solenoids with central thread and detachable coil
  • Valve control spool, position-controlled
  • Integrated pressure sensor plate (optional)
  • Porting pattern according to ISO 4401
  • Analog interface for command and actual value
  • Design for CAN bus with CANopen protocol DS 408 or Profibus-DP
  • Quick commissioning via PC and commissioning software WIN-PED

Type

STW 0195 STW 0196

Size

6 10

Installation position

  any, preferably horizontal

Ambient temperature range

°C

-20 … +50

Storage temperature range

°C

-20 … +80

Weight

kg

2.4 6.5

 

Set-up

The IAC-P valve basically consists of:

Housing (1) with connection surface
Control spool (2) with compression spring (3)
Solenoid and pole tube (4) with central thread
Position transducer (5)
Pressure sensor (6)
Integrated digital control electronics IAC-P (7) with bus connection (X2) and central connector (X1).

Functional description

If solenoids (4) are not operated, spool position A → T (with version "0196-1X/1" additionally B → T)
Functions:
Flow control (Q)
Pressure control (p)
Substitutional control p/Q
The command value presetting can alternatively be specified via an analog interface (X1) or via the field bus interface (X2, X3).
The actual value signals are provided via an analog interface (X1) and can additionally be read out via the field bus (X2, X3).
The controller parameters are set via the field bus (X2, X3).
Separate supply voltage for bus/controller and power part (output stage) for safety reasons

 

The digital integrated control electronics enables the following error detection (diagnosis):

Cable break of pressure sensor supply line (6)
Undervoltage
Cable break position transducer (5)
Communication error
Watchdog
Cable break of command value inputs

The following additional functions are available:

Pressure ramp
Internal command value profile
Enable function analog / digital
Error output 24 V

 

WINPED PC program

To implement the project planning task and to parameterize the IAC-P valves, the user may use the WINPED commissioning software (see accessories):

Parameterization
Diagnosis
Comfortable data management on a PC
PC operating systems: Windows 2000 or Windows XP

Qsoll

Q-Steuerung

p-Regelung

< 12 mA

A → T

inactive

> 12 mA

Substitutional closed-loop control: (A → T or P → A)
Q control (Qcommand) with pressure limitation (pcommand)
The following applies with active pressure limitation: Qactual ≤ Qcommand

Important notice:

The PG fitting (11) must not be opened. Mechanical adjustment of the adjustment nut located below is prohibited and damages the valve!