Module for monitoring and limiting the solenoid currents with proportional valves VT-MUXA2-2-1X

min-slider-1

Module for monitoring and limiting the solenoid currents with proportional valves VT-MUXA2-2-1X

  • Component series 1X
  • Shut-off of the solenoid currents after exceedance of the admissible maximum current
  • Additional, not safety-relevant command value correction prevents early switch-off of the solenoid currents
  • Additional fuse protection of the solenoid circuits by non-exchangeable fuses 1.25 A, fast-acting according to IEC 60127-4
  • Redundant relay contacts per solenoid circuit
  • Redundant solenoid current measurement per solenoid circuit
  • Reverse polarity protection of the solenoid circuits
  • Reverse polarity protection of the operating voltage
  • Reset input – edge-triggered
  • Differential input
  • Command value output
  • OK output
  • Top hat rail mounting
  • Pluggable connection terminals

General

Component series

  1X

Operating voltage

Operating voltage

Nominal value

UB

  24 VDC

Maximum value

U(t)max

  30 V at 0 °C ≤ ϑU ≤ 40 °C 1)

Minimum value

U(t)min

  18 V at 0 °C ≤ ϑU ≤ 40 °C 1)

Reverse polarity protection

    yes

Power consumption

P

VA

< 5

Current consumption

I

A

< 0.2

Fuse/short-circuit protection

1 or 2 fuses for the solenoid currents, not exchangeable

I

  1.25 A fast-acting (SMD)

Display LEDs (green)

OK

    Is illuminated if the self-test has been completed, the relays have operated and there is no error

power

    Is illuminated if the internal power supply unit works
1) see also derating characteristic curve on page 7

Inputs

Command value differential input

 

U

  0 … +10 V or 0 … ±10 V, RE = 100 kΩ

Reset input

Low

UR

  0 … 6.5 V

High

UR

  10 V … UB

1 or 2 monitored solenoid current inputs

Admissible common-mode voltage

U

  –2 V … UB

Reverse polarity protection

    by means of diodes

Admissible clock frequency of the solenoid currents

    0 … 500 Hz

Outputs

Command value output 1)

U

  0 … +10 V or 0 … ±10 V, I = 2 mA

2 solenoid current outputs

I

  1.0 A (monitored to ±2 %)

OK output

High = OK

    UB – 3 V / 50 mA, short-circuit-proof

Low = OK

    < 2 V, Ri = 10 kΩ
1) Command value presetting at the amplifier

Other information

Clearances and creepage distances

    according to EN 50178

admissible degree of contamination

    2 according to EN 60664

Anschlussart

    16-pole terminal housing with detachable terminals

Connection cross-section

A

  0.2 … 2.5 mm2

Mounting type

    Top hat rail TH 35-7.5 according to EN 60715

Protection class

    IP 20

Dimensions (W x H x D)

    see unit dimensions on page 8

Operating temperature range 1)

ϑ

°C

 0+50

Storage temperature range

ϑ

°C

-25 … +85

Weight

m

kg

0.15
1) see also derating characteristic curve on page 7

For applications outside these parameters, please consult us!

Use

The VT-MUXA2-2 module can be used to monitor 1 or 2 solenoid circuits. The solenoid currents are limited so that there is no overheating of the solenoids. The solenoid currents necessary for operating the valve are provided by an amplifier (order separately).

The amplifier is adjusted according to the rated current data of the solenoid (rated current = 1.03 A). With a command value presetting of 10 V, it provides an output current of 1.0 A.

In case of defect or incorrect operation, the amplifier may provide a current of more than 1.0 A. The interconnected VT-MUXA2-2 monitoring module recognizes the over-current, reduces the command value or switches off the solenoid current.

The VT-MUXA2-2 monitoring module must be protected against voltage peaks from the 24 V mains. Our VT 11110 capacitor module protects against voltage peaks and smooths the 24 V supply voltage.

Explosion hazard in case of incorrect assembly!

Please observe the following rules under any circumstances!

The Rexroth electronics listed in this data sheet must be installed and operated outside the potentially explosive area.
1.
The VT-MUXA2-2 module must be switched between amplifier output and solenoids and between control output (command value presetting by superior control) and amplifier input (see block diagram).
2.
Only connect valve solenoids the maximum current of which complies with the monitoring current of the VT-MUXA2-2 monitoring module.
3.

Notice:

The VT-MUXA2-2 module is an electrostatically endangered component. It has to be assembled complying with ESD protective measures.