HESS Hydraulic Equipment Systems and Solutions

Гидравлическое Оборудование Системы и Решения

img
img

Обратная связь

ФИО* e-mail* Телефон* Организация Содержание запроса* Прикрепить файл Выберите файл Введите число с картинки* поменять картинку

Каталог продукции

Бренды

Hydraulic drive power units, low-noise compact units, "silent power units" ABFAG-V

min-slider-1

Hydraulic drive power units, low-noise compact units, "silent power units" ABFAG-V

  • Tank size 160 … 1000 l
  • Component series 1X
  • Vertical design
  • Very low-noise compact unit
  • Tank in U form with pump-motor group fastened in a vibration-isolated manner
  • Actuator ports end at an elastically mounted bulkhead panel
  • Good degasification of the hydraulic fluid
  • Separate filter cooling circuit
  • Very good accessibility

Line connections

Oil side

Connection thread according to ISO 1179, pipe connections according to DIN 2353/ISO 8434, flanges according to ISO 6162

Water connections

Connection thread according to ISO 1179, pipe connections according to DIN 2353/ISO 8434, flanges according to ISO 6162

Pump type

 

A10VSO 18 according to data sheet RE 92712
A10VSO 28 … 140 according to data sheet RE 92711

Circulation unit

PVV 18 … 60 according to data sheet RE 10335

Type of piping

Fitting according to DIN 2353; light/heavy series; type Walform

Hydraulic fluid 1)

Mineral oil (HL, HLP) according to DIN 51524; fast bio-degradable hydraulic fluids according to VDMA 24568 (see also RE 90221) HETG (rape seed oil); HEPG (polyglycols); HEES (synthetic esters)

Hydraulic fluid temperature range 2)

°C

+0 … +80

Pressure limitation

Pump safety valve according to data sheet RE 25890 for variable displacement pumps type A10VSO

Coolant

Potable, process, stream and river water

Motor voltage/frequency 3)

400/690 V-D/Y-50 Hz; 460 V-D-60 Hz

Direction of rotation of pump

Right

Water valve

Electrically operated 2/2 directional water valve according to AB 21-23

Viscosity range 4)

Ideal

mm²/s

16 …  36

short-time

mm²/s

10 … 1.000 4)

Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 5)

Class 21/18/15 according to ISO 4406 (c)

Filter rating

µm

10

Surface protection

1st primer coat

all steel components with zinc dust paint

2nd primer coat

Epoxy basic color RAL 5010 (RN 123.01)
1) Other hydraulic fluids upon request.
Please observe our provisions according to data sheet 07075.
2) The optimum operating temperature of the power unit for operation with mineral oil HLP according to DIN 51524 lies between 40 … 50 °C. In continuous operation, the operating temperature is not to exceed 70 °C.
3) Other voltages upon request; design B 35
4) See also R.92711; R.92712 and R.10335
5) The cleanliness classes specified for the components must be adhered to in hydraulic systems. Effective filtration prevents faults and at the same time increases the life cycle of the components.
For the selection of the filters see catalog sheets R.50070, R.50076, R.50081, R.50086 and R.50088.

Set-up

The tank is designed in U form and fastened in the pump-motor group in a vibration-insulated manner. Due to the good decoupling of structure-borne sound, the tank walls are only slightly excited so that there is no notable sound emission of the system. One sound insulation wall to the top and one to the front allow for the unusually low value. They allow for easy access to the drive unit.

General information

– The actuator ports end at an elastically mounted bulkhead panel.

– The enlarged wall areas provide for good degasification of the hydraulic fluid.

Attachment of control systems

Space for additional control systems is provided at the longitudinal sides, at the back and on the tank top side.

Space for attachments such as hydraulic accumulators, etc. is provided at the broad and/or longitudinal side.

Cooling

The power share of the system converted into heat is dissipated by oil-water heat exchangers. 1)

The heat exchangers are arranged in a separate filter cooling circuit. The separate circuit ensures permanent filtration and cooling.

Вернуться на уровень выше