Бренды
Control modules for clamping and drive modules UPE2 IH15BA
Control modules for clamping and drive modules UPE2 IH15BA
-
Component series 1X
-
Maximum operating pressure 500 bar
-
Maximum flow 14 l/min
- Compact design
- No piping of the control
- Few joints
- Variable set-up
- Can be combined individually
- Direct attachment to the clamping and drive module, external attachment possible, as well
- Direct mounting on drive unit tank cover
- Ready for connection
Installation position 1) |
any | |||
Hydraulic fluid |
Mineral oil (HL, HLP) according to DIN 51524 part 2; other hydraulic fluids upon request | |||
Hydraulic fluid temperature range 2) |
°C |
-20 … +80 | ||
Ambient temperature range |
°C |
+50 … -30 | ||
Viscosity range 1) |
mm²/s |
2,8 … 500 | ||
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 1) |
Class 20/18/15; class 18/16/13 applies to SPDB and SPDR; according t ISO 4406 (c) | |||
Valve pressure rating |
Refer to the related data sheet | |||
Maximum flow of the directional seat valves type: KSDR1... |
2/2 directional seat valve |
qV |
l/min |
20 |
3/2 directional seat valve |
qV |
l/min |
12 | |
Voltage type |
Direct voltage | |||
Available voltages 3) |
U |
V |
24 | |
Voltage tolerance (nominal voltage) |
% |
± 10 | ||
Power consumption 1) |
P |
W |
19 | |
P 1) |
W |
30 | ||
Switching time according to ISO 6403 |
ON |
T |
ms |
25 … 80 |
OFF |
T |
ms |
10 … 25 | |
Switching frequency |
up to 15,000 switching cycles per hour | |||
Protection class according to DIN 40050 4) |
IP65 | |||
Coil temperature 5) |
°C |
150 |
The IH15A control modules for the UPE2 clamping and drive module (51142) serve the realization of complete hydraulic controls. They can be fitted and mounted individually. The directional valve modules and seat valve modules can be combined.
The control modules allow for direct attachment to the UPE2 clamping and drive module. Using the modules for external attachment, the hydraulic controls can, however, also be installed arbitrarily into every system. The reducing module type RBAIH15A allows for direct attachment of the IH15A modules to the tank cover of a conventional drive unit. Using the reducing module type RIH15AR, the hydraulic control can be attached to one control of the IH15B control module family.
The modules have preferably been designed for hydraulic controls for low-flow actuators up to a flow of 14 l/min. They are connected by means of two tie rods.