Бренды
Motor-pump groups - IE2, for continuous operation S1 ABAPG-A10VSO...VS
Motor-pump groups - IE2, for continuous operation S1 ABAPG-A10VSO...VS
-
Pump type A10VSO
-
Series 32
-
Size 45 … 180
-
Electric motor frame size 132M … 315M
- For hydrostatic drives in the open circuit
- Electric motor, design IM B3/B5 (ABAPG)
- Pump fastened at the electric motor with rigid pump carrier and coupling
- Low operating noise
- Versatile possible applications on tank, base frame or separate installation
- Clear, maintenance-friendly set-up
- With axial piston pump A10VSO (variable displacement pump), shock and vibration absorber type
- Adjustment of DRS (hydraulic flow controller) and LA6DS (power controller with pressure cut off)
Line connections |
see table Line connections | |||||
Hydraulic fluid 1) |
Mineral oil HLP according to DIN 51524; part 2 e.g. with operating temperature 50 °C ISO VG46 DIN ISO 3448 |
|||||
Pump type |
|
A10VSO series 32 according to data sheet 92714 | ||||
Direction of rotation |
R = clockwise | |||||
Operating pressure, absolute |
Inlet |
pmin-max 2) |
bar |
0,8 ... 10 | ||
pmin-max 3) |
bar |
1 ... 10 | ||||
Outlet |
pnom |
bar |
280 | |||
Peak pressure |
pmax |
bar |
350 | |||
Leakage port |
pmax |
bar |
2 | |||
Hydraulic fluid temperature range, observe viscosity range 4) |
|
ϑ |
°C |
-25 … +90 | ||
Toptimal with HLP 46 (DIN 51524) |
ϑ |
°C |
+40 … +55 | |||
Tmax in continuous operation |
ϑ |
°C |
+ 65 | |||
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 5) |
At least cleanliness class 20/18/15 must be achieved. | |||||
Viscosity range |
Ideal |
v |
mm²/s |
16 … 36 | ||
short-term 6) |
v |
mm²/s |
10 … 1.000 | |||
Electric motor |
Motor type |
Three-phase asynchronous motor | ||||
Efficiency class |
IE2 | |||||
Number of pole pairs |
4 | |||||
Voltage according to IEC 38 |
U |
|
V |
400 | ||
at 50 Hz (CB) |
V |
690 | ||||
Speed |
n |
at 50 Hz |
rpm |
1450 | ||
Protection class |
IP55 | |||||
Installation position |
horizontal | |||||
Surface treatment |
By default, all steel components and components are at least provided with temporary corrosion protection (e.g. for transport). |