Inline filter with filter element according to DIN 24550 245 LE(N)

min-slider-1

Inline filter with filter element according to DIN 24550 245 LE(N)

  • Size 0040 … 0400
  • Max. operating pressure 250 bar
  • Flow, max. 420 l/min
  • Port G 1/2, G 1, G 1, G1 1/4, G1 1/4, G1 1/2, G1 1/2, G1 1/2
  • Operating temperature -10 … +100 °C
  • Filters for inline installation
  • Special highly efficient filter media
  • Filtration of very fine particles and high dirt holding capacity across a broad pressure differential range
  • High collapse resistance of the filter elements
  • Standard version equipped with mechanical/visual maintenance indicator with memory function
  • Optional equipment with various electrical switching elements, modular design
  • Optional bypass valve integrated in the filter housing
  • High filtration performance due to the tangential cyclone-effect flow path

Size

0040 0063 0100 0130 0150 0160 0250 0400

Installation position

    vertical

Ambient temperature range

ϑ

°C

-10 … +65

Weight

m

kg

3.77 4.83 5.64 8.88 9.52 13.99 15.53 18.52

Volume

 

l

0.21 0.38 0.53 0.76 0.96 1.13 1.6 2.4

Material

Filter head

    GGG

Filter bowl

    Steel

Seals

    NBR / FKM

 

The 245LE(N) inline filter is suitable for inline installation.

It basically consists of filter head (1), a screwable filter bowl (2), filter element (3) as well as mechanical/visual maintenance indicator (4). In case of filters with low-pressure-differential-stable filter elements (= code letter pressure differential A), there is an assembled bypass valve (5) by default.

Via the inlet, the fluid reaches the filter element (3) where it is cleaned. The dirt particles filtered out settle in the filter element (3). Via the outlet, the filtered fluid enters the hydraulic circuit.

The filter housing and all connection elements are designed so that pressure peaks - as they may e.g. occur in case of abrupt opening of large control valves due to the accelerated fluid quantity - can be securely absorbed. As of size 0160, the standard equipment comprises a drain screw (7).

By default, the filter is equipped with mechanical/visual maintenance indicator (4). The electronic switching element (8) which has to be ordered separately is attached to the mechanical/visual maintenance indicator (4) and held by means of a locking ring.

The electronic switching elements with 1 or 2 switching points are connected via a mating connector according to IEC-60947-5-2 or via a cable connection according to EN17301-803.

Notice!

If the maintenance indicator for the element exchange is not observed, the bypass valve will open if the pressure differential increases. In this way, one part of the flow reaches the clean side of the filter without being filtered. Thus, effective filtration is no longer guaranteed.