Бренды
Block mounting filter, for sandwich plate mounting 320 PZ
Block mounting filter, for sandwich plate mounting 320 PZ
-
Size 06/025, 06/025, 10/075, 10/125
-
Max. operating pressure 320 bar
-
Flow, max. 42 l/min
-
Operating temperature -10 … +100 °C
- Filter für Zwischenplatteneinbau, Filtertopf links oder rechts
- Special highly efficient filter media
- Filtration of very fine particles and high dirt holding capacity across a broad pressure differential range
- High collapse resistance of the filter elements
- Standard version equipped with mechanical/visual maintenance indicator with memory function
- Optional equipment with various electrical switching elements, modular design
- Lage der Anschlüsse nach ISO 4401-03-02-0-05 (NG6) oder ISO 4401-05-04-0-05 (NG10)
- High filtration performance due to the tangential cyclone-effect flow path
Size |
06/025 | 06/025 | 10/075 | 10/125 | |||
Installation position |
Sandwich plate mounting | ||||||
Ambient temperature range |
-10 … +65 °C | ||||||
Material |
Filter head |
GGG | |||||
Filter bowl |
Steel | ||||||
Seals |
NBR / FKM | ||||||
Fatigue strength according to ISO 10771 |
Load cycles |
> 10⁶ with operating pressure | > 10⁶ with operating pressure | > 10⁶ with operating pressure | > 10⁶ with operating pressure | ||
Weight |
m kg |
3.5 | 3.5 | 6.5 | 7.2 | ||
Volume |
0.14 l | 0.14 l | 0.35 l | 0.48 l |
Block mounting filters for sandwich plate mounting are intended for installation in vertical stackings. They basically consist of filter head (1), a screwable filter bowl (2), filter element (3) as well as mechanical/visual maintenance indicator (4). Via the inlet bore (bore P / sealing side), the hydraulic fluid reaches the filter element (3) where it is cleaned. The dirt particles filtered out settle in the filter bowl (2) and in the filter element (3). On the opposite side, the filtered hydraulic fluid enters the hydraulic circuit via the outlet bore. In size 06/025, the filter type 320PZ is available in two versions, left or right.
The filter housing is designed so that pressure peaks – as they may e.g. occur in case of abrupt opening of large control valves due to the accelerated fluid weight – can be securely absorbed. The filter material H…PZ is especially suitable for flow fluctuations which are common in this application.
By default, the filter is equipped with mechanical/visual maintenance indicator (4). The electronic switching element (5) which has to be ordered separately is attached to the mechanical/visual maintenance indicator (4) and held by means of a locking ring. The electronic switching elements with 1 or 2 switching points are connected via a mating connector according to IEC-60947-5-2 or via a cable connection according to EN 17301-803.
Notice:
Assignment of the connection designation see chapter “Dimensions”.