Block mounting filter, for lateral flange-mounting 350 PSF(N)
Block mounting filter, for lateral flange-mounting 350 PSF(N)
-
Size 0040 … 1000
-
Max. operating pressure 350 bar
-
Flow, max. 490 l/min
-
Port DN20, DN20, DN38, DN38, DN38, DN38, DN38, DN32, DN32
-
Operating temperature -10 … +100 °C
- Special highly efficient filter media
- Adsorption of finest particles over a wide pressure differential range
- High contamination retention capacity due to large specific adsorption surface
- High collapse resistance of the filter elements
- Standard version equipped with mechanical/visual maintenance indicator with memory function
- Flow-optimized design due to 3D computer-supported design
- Good chemical resistance of the filter elements
Size |
0040 | 0063 | 0100 | 0160 | 0250 | 0400 | 0630 | 1000 | 0130 | 0150 | |||
Standard port |
DN20 | DN20 | DN38 | DN38 | DN38 | DN38 | DN38 | DN32 | DN32 | ||||
Installation position |
vertical | ||||||||||||
Material |
Filter head |
GGG | |||||||||||
Filter bowl |
Steel | ||||||||||||
Seals |
NBR / FKM | ||||||||||||
Fatigue strength according to ISO 10771 |
Load cycles |
> 1 m load cycles | > 1 m load cycles | > 1 m load cycles | > 1 m load cycles | > 1 m load cycles | > 1 m load cycles | > 1 m load cycles | > 1 m load cycles | > 1 m load cycles | > 1 m load cycles | ||
Weight |
m kg |
5.5 | 6.2 | 7 | 18.5 | 20.5 | 24.5 | 41.2 | 87 | 13 | 13.9 | ||
Volume |
0.3 l | 0.45 l | 0.65 l | 1.65 l | 2.1 l | 3.2 l | 4.4 l | 6.3 l | 0.9 l | 1.1 l |
Block mounting filters are suitable for direct attachment to pump blocks and manifolds. They are installed upstream open-loop or closed-loop controllers to be protected. They basically consist of filter head (1), a screwable filter bowl (2), filter element (3) as well as mechanical/visual maintenance indicator (4). In case of filters with low-pressure-differential-stable filter elements (= code letter pressure differential A), there is also an assembled bypass valve (5). Via port I, the hydraulic fluid reaches the filter element (3) where it is cleaned. The dirt particles filtered out settle in the filter bowl (2) and in the filter element (3). Via port 0, the filtered hydraulic fluid enters the hydraulic circuit. The filter housing and all connection elements are designed so that pressure peaks – as they may e.g. occur in case of abrupt opening of large control valves due to the accelerated fluid quantity – can be securely absorbed. As of size 0160, the standard equipment comprises an oil drain plug (7). With size 1000, the filter bowl has a two-part set-up. Basically, the filter is equipped with mechanical/visual maintenance indicator (4). The electronic maintenance indicator is connected via the electronic switching element with 1 or 2 switching points (6), which has to be ordered separately. The electronic switching element is attached to the mechanical/visual maintenance indicator and held by means of a locking ring. From size 0130, 2 minimess connections can be ordered via supplementary information in the type key.