HESS Hydraulic Equipment Systems and Solutions

Гидравлическое Оборудование Системы и Решения

img
img

Обратная связь

ФИО* e-mail* Телефон* Организация Содержание запроса* Прикрепить файл Выберите файл Введите число с картинки* поменять картинку

Каталог продукции

Бренды

Backpressure indicators for return line filters WO-S01

min-slider-1

Backpressure indicators for return line filters WO-S01

  • Max. operating pressure 10 bar
  • Operating temperature -30 … +100 °C
  • Modular structure
  • Mechanical/visual indicators WO with one switching point and memory function

Type / version

WO-S01-0,8-M-10 WO-S01-0,8-V-10 WO-S01-1,5-M-10 WO-S01-1,5-V-10 WO-S01-2,2-M-10 WO-S01-2,2-V-10 WO-S01-2,2-M-10-PA WO-S01-2,2-V-10-PA

 

Type / version

WO-S01-0,8-M-10 WO-S01-0,8-V-10 WO-S01-1,5-M-10 WO-S01-1,5-V-10 WO-S01-2,2-M-10 WO-S01-2,2-V-10 WO-S01-2,2-M-10-PA WO-S01-2,2-V-10-PA

Type of pressure measurement

      Back pressure

Operating pressure

max.

pmax

bar

10

Switching pressure

   

bar

0.8 1.5 2.2

Switching pressure tolerance

   

bar

± 0.15 ± 0.2 ± 0.3 ± 0.44 ± 0.3

Operating temperature range

   

°C

-30 … +100

Material

      Aluminium PA6.6

Material

Seals

    NBR FKM NBR FKM NBR FKM NBR FKM

Tightening torque

max.

MA max

Nm

50

 

By default, the Rexroth filters are supplied with a mechanical/visual maintenance indicator (WO). The electronic switching element (WE) is available as accessory and compatible with all mechanical/visual maintenance indicators. The electronic switching element is attached to the visual maintenance indicator and fixed by means of a locking ring. The electronic maintenance indicator is not dependent on the nominal pressure of the filter.

The increasing back pressure and/or pressure differential pushes a piston (1) against a spring (2) upwards. The solenoid (3) mounted on the piston is moved together with the piston. The visual pin (4) may take two valid positions. If the position of the piston (1) with solenoid (3) is below the nominal pressure of the maintenance indicator, the visual pin remains in retracted “rest position”. Upon first exceedance of the nominal pressure, the position of the visual pin (5) is changed rapidly into the second possible “On condition” by repellence of the solenoid of the pin (5) to the solenoid of the piston (3). The pin will permanently remain in this extended position, even visible after machine switch-off (or pressure drop, cold start) (memory function). It has to be acknowledged.