Бренды
Filter cooler unit with inline filter according to DIN 24550 ABUKG
Filter cooler unit with inline filter according to DIN 24550 ABUKG
-
Component series 4X
-
Electric motor frame size 90S … 132S
-
Maximum operating pressure 10 bar
-
With gerotor pump, external gear pump SILENCE PLUS or screw spindle pump
-
With low-pressure inline filter
-
With plate heat exchanger
- Compact unit with pump, installed low-pressure filter and plate heat exchanger
- Modular design
- Set-up as required with console or on installation plate
- Low-noise versions available
Line connections |
Oil side |
Connection thread according to ISO 1179, pipe connections according to DIN 2353/ISO 8434, flanges according to ISO 6162 | ||
Water side |
Thread according to ISO 228/1 | |||
Type of piping |
Fitting according to DIN 2353; light/heavy series With ABUKG-V: Precision steel pipes according to DIN 2391/C, DIN EN ISO 1127 |
|||
Hydraulic fluids 1) |
Mineral oil HLP46 according to DIN 51524, part 2 | |||
Hydraulic fluid temperature range 2) |
°C |
25 … 80 | ||
Installation position |
Vertical | |||
Coolant |
Potable, process, stream and river water (filtration recommended) Cooling water demand at least: VK=0.5 x Voil [l/min] (min. 0.1 bar at the water valve) Heating (H2O):Δv=14 x power loss (kW)/VK [°K] |
|||
Adm. operating pressures at input (absolute) 4) 3) |
Oil side |
Gerotor pump |
bar |
0,7 ... 2 |
Screw spindle pump |
bar |
0,3 ... 4 | ||
External gear pump SILENCE PLUS |
bar |
0,7 ... 3 | ||
pmax |
bar |
10 | ||
Water side |
bar |
16 4) | ||
Motor voltage/frequency |
4 … 45 kW cooling power |
V |
230 400 |
|
55 ... 75 kW cooling power |
V |
400 690 |
||
Direction of rotation of pump |
Right | |||
Water valve |
Type ABZAW-G1-G24K4 according 50235 (included in the scope of delivery) | |||
Maximum admissible degree of contamination of the hydraulic fluid, cleanliness class according to ISO 4406 (c) 5) |
At least cleanliness class 20/18/15 must be achieved. | |||
Filter rating 6) |
µm |
10 | ||
Surface treatment |
By default, all steel components and components are at least provided with temporary corrosion protection (e.g. for transport). |
The units are fitted with a low-pressure filter. Electrical maintenance indicators signal when an element has to be exchanged. The water consumption depends on the utilization of the power unit and the inlet temperature difference.
The water supply for cooling purposes is regulated by an electrically operated water valve. Circulation units of version ABUKG-...K are optionally fitted with a collecting pan for collecting oil losses during filter exchanges.