Size 10
-
Component series 3X
-
Max. operating pressure 350 bar
-
Nominal flow 50 l/min, 80 l/min
- Reliable - proven and robust design
- Energy-efficient - no pilot oil demand, high flows with low pressure differential
- Flexible - suitable for position and velocity control
- Precise - high response sensitivity and little hysteresis
- Safe - shut-off of the second solenoid by means of ISA adapter possible
Type |
4WRPE | ||
Size |
10 | ||
Component series |
3X | ||
Design |
Directional spool valve, direct operated | ||
Type of actuation |
Proportional solenoid with position control, OBE | ||
Anschlussart |
For subplate mounting: Porting pattern according to ISO 4401 | ||
Installation position |
Any | ||
Earth |
Valve with one solenoid |
kg |
6 |
Valve with two solenoids |
kg |
7.6 | |
Storage temperature range |
°C |
+10 … +40 | |
Ambient temperature range |
°C |
-20 … +60 | |
Sine test according to DIN EN 60068-2-6 |
10...2000...10 Hz / maximum 10 g / 10 cycles / 3 axes | ||
Random test according to DIN EN 60068-2-64 |
20...2000 Hz / 10 gRMS / 30 g peak / 30 min / 3 axes | ||
Shock test according to DIN EN 60068-2-27 |
15 g / 11 ms / 3 axes | ||
Maximum relative humidity 1) |
% |
95 | |
MTTFd values according to EN ISO 13849 |
yrs |
150 |
The valve type 4WRPE is a direct operated directional control valve with electric position feedback and integrated electronics (OBE).
Set-up
The valve basically consists of:
Function
The integrated electronics (OBE) compares the specified command value to the position actual value. In case of control deviations, the relevant solenoid will be activated. Due to the changed magnetic force, the control spool (2) is adjusted against the corresponding spring. Stroke/control spool cross-section is controlled proportionally to the command value. In case of a command value presetting of 0 V, the electronics adjust the control spool (2) to central position.
Error detection
In the following cases of error, the electronics will de-energize the control solenoids:
The control spool (2) is kept in the mechanical central position by the compression springs (3.1 and 3.2) (does - with symbol V - not correspond to the hydraulic central position).
4/3-way version
The valve type 4WRPE is a direct operated directional control valve with electric position feedback and integrated electronics (OBE).
Set-up
The valve basically consists of:
Function
The integrated electronics (OBE) compares the specified command value to the position actual value. In case of control deviations, the control solenoid will be activated. Due to the changed magnetic force, the control spool (2) is adjusted against the control spring. Stroke/control spool cross-section is controlled proportionally to the command value. With a positive command value presetting, the valve opens from P to B or A to T. Negative command values lead to no change in the control spool position.
Error detection
In the following cases of error, the electronics will de-energize the control solenoid:
4/2-way version