HESS Hydraulic Equipment Systems and Solutions

Гидравлическое Оборудование Системы и Решения

img
img

Обратная связь

ФИО* e-mail* Телефон* Организация Содержание запроса* Прикрепить файл Выберите файл Введите число с картинки* поменять картинку

Каталог продукции

Бренды

High-response directional valves, direct operated, with electrical position feedback and integrated electronics (OBE) 4WRPEH 6 -2X

min-slider-1

High-response directional valves, direct operated, with electrical position feedback and integrated electronics (OBE) 4WRPEH 6 -2X

  • Size 6
  • Component series 2X
  • Max. operating pressure 315 bar
  • Nominal flow 2 l/min, 4 l/min, 12 l/min, 15 l/min, 24 l/min, 40 l/min
  • 4/4 directional design
  • With control spool and sleeve in servo quality
  • Operated on one side, 4/4 fail-safe position in switched-off condition
  • Electric position feedback and integrated electronics (OBE), calibrated in the factory
  • Electrical connection 6P+PE; signal input differential amplifier with interface "A1" ±10 V or interface "F1" 4 ... 20 mA (Rsh = 200 Ω)
  • Use for electro-hydraulic controls in production and test systems

Type

4WRPEH

Size

6

Component series

  2X

Design

  Directional spool valve, direct operated, with steel sleeve

Type of actuation

  Proportional solenoid with position control, OBE

Anschlussart

  For subplate mounting: Porting pattern according to ISO 4401

Installation position

  Any

Earth

kg

2.7

Ambient temperature range

°C

-20 … +50

Maximum vibration resistance

g

25

MTTFd values according to EN ISO 13849

yrs

150
 

 

General information

The high-response valve type 4WRPEH is a direct operated directional control valve with electric position feedback and integrated electronics (OBE). In the integrated electronics (OBE), the specified command value is compared with the position actual value. In case of control deviations, the stroke solenoid will be activated which - due to the changed magnetic force - adjusts the control spool against the spring. Stroke/control cross-section is controlled proportionally to the command value. In case of a command value presetting of 0 V, the electronics adjusts the control spool against the spring to central position. In deactivated condition, the spring is untensioned to a maximum and the valve is in fail-safe position.

Switch-off behavior

With switched-off electronics, the valve will immediately move into the relevant secured basic position (fail-safe). In this connection, it moves through the switching position P–B/A–T which may result in movements at the controlled component. This has to be considered in the system design.

1

Control solenoid with position transducer

2

Valve body

3

Connector for possible 2nd stage

4

Mating connector

 

Вернуться на уровень выше