4/3 proportional directional valves with integrated digital electronics and field bus interface (IFB-P) 4WREF

min-slider-1

4/3 proportional directional valves with integrated digital electronics and field bus interface (IFB-P) 4WREF

  • Size 6, 10
  • Component series 2X
  • Maximum operating pressure 315 bar
  • Maximum flow 180 l/min
  • Direct operated proportional directional valve with integrated digital electronics and field bus interface (Integrated Field Bus IFB-P)
  • Operation by means of proportional solenoids with central thread and detachable coil
  • Valve control spool, position-controlled
  • Analog interface for command and actual value
  • Command value (flow), analog or via bus
  • Design for CAN bus with CANopen protocol DS 408 or Profibus-DP
  • Quick commissioning via PC and WIN-PED 6 commissioning software

Type

4WREF

Size

6 10

Installation position

  any, preferably horizontal

Ambient temperature range

°C

-20 … +50

Storage temperature range

°C

-20 … +80

Weight

without sandwich plate

kg

2.4 6.5

Climate

  Environmental audit according to EN 60068-2

MTTFd values according to EN ISO 13849

y

150

 

Set-up:

The valve basically consists of:

Housing (1) with connection surface
Control spool (2) with compression springs (3 and 4) and spring plates (8 and 9)
Coils (5 and 6) and pole tubes (10 and 11) with central thread
Position transducer (7)
Integrated digital control electronics IFB-P (12)

Functional description

With de-energized solenoids (5 and 6), the control spool (2) is brought into the central position by compression springs (3 and 4) between the spring plates (8 and 9) (with V control spool without spring plate). With V control spools, the mechanical zero position does not correspond to the hydraulic one.

Functions:

Control of the valve spool position
The command value presetting can alternatively be specified via an analog interface (X1) or via the field bus interface (X2, X3)
The actual value signals are provided via an analog interface (X1) and can additionally be read out via the field bus (X2, X3)
The controller parameters are set via the field bus

The integrated digital electronics enables the following error detection:

Undervoltage
Cable break position transducer (7)
Communication error
Watchdog
Cable break command value input (only with current interface)

The following additional functions are available:

Ramp generator
Internal command value profile
Enable function, digital
Overlap compensation
Zero point correction

WIN-PED PC program (version 6 or higher):

To implement the project planning task and to parameterize the IFB-P valves, the user may use the WIN-PED commissioning software.

Parameterization
Diagnosis
Comfortable data management on a PC

System requirements

IBM PC or compatible system
Windows 2000 or Windows XP
RAM (recommendation: 256 MB)
150 MB of available hard disk capacity

Notice

The "WIN-PED" PC program is not included in the scope of delivery. It is available for free download!

Important notice:

The PG fitting (13) must not be opened. Mechanical adjustment of the adjustment nut located below is prohibited and damages the valve!