Бренды
Modular standard power units ABSKG
Modular standard power units ABSKG
-
Tank size 20 l, 40 l, 60 l
- Stable aluminum tank
- Modular design
- Compact power unit design
- Individual adaptation possible
- Versatile possible applications
- Additional options possible
- Clear, maintenance-friendly arrangement
Tank size |
l |
20 | 40 | 60 | ||
Line connections |
Connection thread according to ISO 1179 (DIN 3852-2 form X) and/or pipe connections according to ISO 8434 part 1 | |||||
Hydraulic fluid 1) |
Mineral oil HLP according to DIN 51524; part 2 e.g. with operating temperature 50 °C ISO VG46 DIN ISO 3448 |
|||||
Return flow filter with filter element according to DIN 24550 according to data sheet 51424 |
Containers |
l |
20 | 40 | 60 | |
|
10TEN0040-H10XLA00-V2,2-M-R3… | 10TEN0063-H10XLA00-V2,2-M-R3… | 10TEN0063-H10XLA00-V2,2-M-R3… | |||
Filter rating |
Breathing filter |
µm |
10 | |||
Return flow filter |
µm |
10 | ||||
Viscosity range with pump type: |
AZPB; AZPF 2) |
mm²/s |
12 … 800 | |||
GF2 |
mm²/s |
10 … 300 | ||||
R4 |
mm²/s |
10 … 200 | ||||
Required cleanliness class for basic power units with pump type 3) |
20/18/15 according to ISO 4406 | |||||
Electric motor |
Motor type |
Three-phase asynchronous motor | ||||
Efficiency class |
IE1 |
kW |
0.37 | |||
IE3 |
kW |
0,75 … 7,5 | ||||
Voltage according to IEC 38 U |
≤ 3 kW, 50 Hz |
V |
230 400 |
|||
≥ 4 kW, 50 Hz |
V |
400 690 |
||||
Number of pole pairs |
4 | |||||
Speed |
rpm |
1450 | ||||
Protection class |
IP55 | |||||
Heat exchanger |
Type |
Oil-air | ||||
Max. operating pressure |
bar |
16 | ||||
Type of piping |
Tube forming system for fittings with 24° cone connection or double-edge cutting ring according to ISO 8434 part 1 (DIN 2353) easy/heavy series according to the technical possibilities | |||||
Surface treatment |
Steel components pipes; |
Cr(VI)-free metal surface coatings | ||||
Oil pan steel design |
Single coat RAL 5010 | |||||
Tank aluminum cast |
without additional surface treatment | |||||
Connection manifold |
Phosphate coating according to DIN EN 12476 | |||||
Components |
Remain in the as-delivered state by the manufacturer. This offers at least temporary corrosion protection. |