HESS Hydraulic Equipment Systems and Solutions

Гидравлическое Оборудование Системы и Решения

img
img

Обратная связь

ФИО* e-mail* Телефон* Организация Содержание запроса* Прикрепить файл Выберите файл Введите число с картинки* поменять картинку

Каталог продукции

Бренды

Float switch with two switching contacts and one temperature contact ABZMS-35

min-slider-1

Float switch with two switching contacts and one temperature contact ABZMS-35

  • Component series 1X

Medium temperature range

°C

 0 …  90

Installation position

vertical ±10°

Ambient temperature range

°C

-30 … +50

Material

Pipe and thermostat

  Cu alloy

Float

  PUR hard foam

Flange

  Cu alloy

Seal material

NBR seals

Maximum switching point L1

mm

400

Weight with L1 = 300 mm

kg

0.16

 

Float switches are switching devices operated by a float moved by fluid. They are used to control the tank fluid levels in small power units type ABSKG ... NG10; 20; 40 and 60.

The sliding tubes contain two fixedly set reed contacts (normally closed contact and normally open contact) that are switched by the permanent magnets installed in the float.

Fixedly set temperature contacts (option) are fitted to monitor the max. hydraulic fluid temperature.

Function of level switch

When the float reaches the switching points while the oil level is falling, the contacts are operated magnetically. The switching positions of the contacts are maintained until the float passes the switching points again due to a rising oil level.

Switching point L1 is a normally closed contact, the contact function of switching point L2 is optionally a normally closed or normally open contact.

Level switch function

When the float reaches the switching points while the oil level is falling, the contacts are operated magnetically. The switching positions of the contacts are maintained until the float passes the switching points again due to a rising oil level.

Switching point L1 is a normally closed contact, the contact function of switching point L2 is optionally a normally closed or normally open contact.

Temperature contact function

A bimetal plate, which is influenced by temperature, switches when a firmly set response temperature is reached. The temperature contact is not suitable for temperature controlling, but merely for a shutdown function.

Вернуться на уровень выше