Бренды
Electronic contact thermometer ABZMT
Electronic contact thermometer ABZMT
-
Component series 1X
Version |
MS | ES | ||
Temperature range |
°C |
0 … 100 | ||
Ambient temperature range |
°C |
-20 … +70 | ||
Installation position |
any, preferably vertical | |||
Maximum operating pressure |
bar |
5 | 10 | |
Material |
Pipe |
Cu alloy | Stainless steel 1.4571 | |
Flange |
Aluminum, anodized | Stainless steel 1.4571 | ||
Seal material |
NBR | FKM | ||
Maximum sensor length |
mm |
1000 | ||
Sensor connection |
G1/2 | |||
Weight with L1 = 300 mm |
kg |
0.25 | 0.35 |
Electronic contact thermometers are used for the temperature control of hydraulic systems.
The contact thermometers have two or four programmable temperature switching outputs, or alternatively one programmable switching output and one analog output 4 … 20 mA, with display and control unit.
The temperature display can be selected in °C or °F.
Function display and control unit
The microprocessor-controlled display and control unit processes the analog input signals for the analysis of the temperature control. The temperature settings can be made at the control unit in a simple menu tree by means of pushbuttons and read at the LED display.
The display and control unit has a red, four-digit seven-segment LED display and 3 pushbuttons for the operation as well as up to 4 LEDs integrated in the front plate for displaying alarm conditions.
The device has moreover two (T2) or four (T4) freely adjustable PNP switching outputs plus the adjustable switch-back points. One PNP output can be programmed as frequency output. Alternatively one freely programmable PNP switching output and one 4 … 20 mA output for the continuous temperature measurement. The switching conditions are shown in the display that can be rotated by 270° (version D0).
The 4 … 20 mA output can optionally be changed to 0 … 10 V, 2 … 10 V or 0 … 5 V.
In the display, the desired unit (°C, °F) will be shown according to the setting of the measured temperature. By default, the temperature display is set to °C.
During the setting and/or programming of the corresponding process parameters, the parameter values and/or the related menu items will be shown in the display. In case of an energy supply failure, all input values will be stored, the min/max values can be retrieved from a permanent memory, if necessary.
Parameterization
The menu navigation is based on the VDMA standard sheet for fluid sensors 24574-1.
The operating menu is designed hierarchically, as tree structure.
That means that frequently used functions and adjustment points can be accessed very quickly and rarely used menu items can be found in a sub-menu.
Using the ▲ and ▼ keys, the corresponding parameter is set and/or the next menu item is displayed.
Using the ► key, the marked menu item is selected and/or the set parameter is accepted and saved.
The parameter may be a numerical value and a selection of functions (e.g. NO [output as normally open contact], NC [output as normally closed contact] or i1 [analog output 4 … 20 mA]).
After confirmation of a parameter or selection of a function using the ► key, the display switches back to the current menu item. Then, you can display the next menu item using ▲ and ▼ and select it using the ► key.