Бренды
Analog positioning module VT-MACAS-1X
Analog positioning module VT-MACAS-1X
-
Component series 1X
- suitable for controlling valves with installed electronics for position and velocity control
- Design: Module for snapping onto carrier rails
- Enable input
- Cable break detection for actual value cable
- Short-circuit-proof interfaces
- Test points on front plate
- Compensation jump can be switched off
- Position: PT1 control
- Velocity control possible in connection with tachometer (speed indicator): PI control
- Area adjustment cylinder
Power supply |
nominal 24 V= battery voltage 21...40 V, rectified alternating voltage Ueff = 21...28 V (single-phase, full-wave rectifier) |
|||
Current consumption, max. |
mA |
200 | ||
Signal input |
VT-MACAS-500-10/V0 |
Ucommand: ±10 V, differential amplifier Ri= 100 kΩ |
||
VT-MACAS-500-10/V0/l |
Iist: 4...20 mA Rsh = 200 Ω |
|||
Actual value signal |
VT-MACAS-500-10/V0 |
Uactual: ±10 V, differential amplifier Ri= 100 kΩ |
||
VT-MACAS-500-10/V0/l |
Iist: 4...20 mA Rsh = 200 Ω |
|||
Valve signal |
UV= ±10 V (max. 10 mA) or IV= 4...20 mA (middle 12 mA) |
|||
Compensation step |
can be switched off; effective in a range of ±4 % |
|||
Enable signal |
V= |
8,5...40 V | ||
Error message |
no error: 24 Vnom (UB) max. 50 mA error: < 2 V |
|||
IN POS message |
IN POS: 24 Vnom (UB) max. 50 mA not IN POS: < 2 V |
|||
Ramp ranges |
I: 0,1...1 s II: 1...10 s |
|||
Area adjustment AK : AR |
min. 1:1; max. 1:4 | |||
Actual value adjustment |
Zero point: -5...10 % Gain: 50...110 % |
|||
Controller type |
Position: PT1 Velocity: PI |
|||
Zero point valve |
% |
± 5 | ||
Special features |
– Switchable from position to velocity control – Switchable position window – Test points on front plate – Interfaces short-circuit-proof |
|||
Fastening |
Top hat rail TH35-7.5 or G rail G32 according to EN 60715 | |||
Port |
Connectors + terminals | |||
Operating temperature |
°C |
0+70 | ||
Storage temperature range |
°C |
-20 … +70 | ||
Weight |
m |
kg |
0.38 |