HESS Hydraulic Equipment Systems and Solutions

Гидравлическое Оборудование Системы и Решения

img
img

Обратная связь

ФИО* e-mail* Телефон* Организация Содержание запроса* Прикрепить файл Выберите файл Введите число с картинки* поменять картинку

Каталог продукции

Бренды

Hydro-electric piston type pressure switches HED 5 -3X

min-slider-1

Hydro-electric piston type pressure switches HED 5 -3X

  • Component series 3X
  • Maximum operating pressure 400 bar
  • Pressure ratings 25, 63, 100, 200 and 400 bar
  • UL approval
  • CCC approval (except for MT version)
  • 4 pressure ratings
  • Electrical connection with large cubic connector
  • Micro switch with NC/NO contact function
  • Potential-free switching of currents from 1 mA to 2 A

Weight

m

kg

0.2

Installation position

    any

Ambient temperature ranges (NBR seals)

ϑ

°C

-30 … +50

Ambient temperature ranges (FKM seals)

ϑ

°C

-20 … +50

Ambient temperature range (low-temperature seal)

ϑ

°C

-40 … +50

Sine test

    DIN EN 60068-2-6:1996-05, 10...2000 Hz, max. 10 g, 10 double cycles

Transport shock

    DIN EN 60068-2-27:1995-03, half-sine 15 g / 11 ms, 3 x in positive direction, 3 x in negative direction (a total of 6 single shocks per axis)

Noise test

    DIN EN 60068-2-64: 1995-08, 20...2000 Hz, 14gRMS, 24 h

Conformity/certification

CE

    DIN EN 61058-1: 2002 / A2: 2008
DIN EN 60947-1: 2007 / A1: 2011
DIN EN 60947-5-1: 2004 / A1: 2009
DIN EN 60529: 1991 / A2: 2013

UL

    UL, 508 17th edition File No E223220 (up to 350 bar)

CCC

    GB 14048.5-2008

 

Hydro-electric pressure switches of type HED 5 are piston type pressure switches.

They basically consist of housing (1), installation kit with piston (2), compression spring (3), adjustment element (4) and micro switch (5)

The pressure to be monitored acts on the piston (2)

The latter is supported by the spring plate (6) and acts against the continuously adjustable force of the compression spring (3).

The spring plate (6) transmits the movement of the piston (2) onto the micro switch (5). This switches the electric circuit on or off, depending on the circuit set-up.

Notice:

In order to increase the life cycle, the pressure switch should be mounted with low vibrations and protected from hydraulic pressure surges.

 